Lower Pacific Heights, House Addition
Owner-Builder – Mr. Phil Martin
- Complete re-building required upgrading the foundations to Code
- Neighbor's brick footing needed underpinning causing substantial expense and delay
- Introducing helical piers allowed new grade beams to be higher than the neighbor’s footing saving cost time
- Lateral support afforded with opposite retaining wall passive resistance, no tie-backs used
- Selected pull testing was conducted to ensure pier capacities